Marine Coupled

Converter

C POWER FOR MARINE APPLICATIONS

The Hitzinger C-Power marine coupled converter provides absolute power protection to marine applications and provides a ‘clean source of power’ to ships in port. The C-Power rotary converter acts independently from the local network and provides maximum power stability, overload capacity, precision and reliability, together with optional vibration dampers for resilient mountings. The guaranteed high quality supply ensures sensitive on-board equipment is protected to ensure continuous operation.

02. Technical

Engineering Specifications

Full technical breakdown of power ratings, environmental tolerances and configurable variants. Each specification reflects factory-tested data under standardized ISO 8528 conditions; site-specific deratings available on request.
01. Versions
  • There are multiple versions available, including either soundproofed enclosures (for internal placement) or weather-protected enclosures and split versions with freestanding switchgear. Tailored versions are also available upon request (Including special requirements for shock, climate, EMC…)
  • 10 – 2,000 kVA (50/60 Hz)
  • 10 – 3,500 kVA (50/50 or 60/60 Hz)
  • Asynchronous or synchronous motor
  • Input voltage up to 12kV, with Input frequencies of 50 or 60Hz – (Specific input voltages are available upon request)
  • Output voltages up to 12kV AC and 1000VDC, with a Frequency of 16 2/3 Hz – 800 Hz
  • Distortion factor: <1.5 %
  • Standard Noise level is <65 dB (A) @ 7m (Additional Noise reduction kits are further available should you require lower sound attenuation)
  • Ambient temperature: -30 °C to +52 °C
  • Relative humidity: up to 95 %

Multiple constructions are available to suit, including; Vertical, Horizontal, Freestanding with combined switchgear and Top-mounted switchgear (depending on size)

  • Slip rings for variable adjustment of output voltage
  • Soft starter for choke, transformer and frequency converters
  • Frequency converter for variable adjustment of output frequency
  • Standard ISO type Containers (20 ft, 30 ft, 40 ft)
  • Master control (Including Display on PC or touch-panel) and Remote operation
  • Ambient temperature: -30 °C to +52 °C
  • Relative humidity: up to 95 %
  • Standard Noise level is <65-95 dB (A) @ 7m (Additional Noise reduction kits are further available should you require lower sound attenuation)
  • EN-60034

The Hitzinger design philosophy ensures that our rotary converters for test bay applications are characterised by there robust and compact design. The optimised efficiency and the lowest noise emissions, means that we are the preferred partner for many consultants, contractors and clients. The Hitzinger converters are designed specifically to provide the lowest maintenance regime and offer extremely easy servicing and operation throughout the life of the equipment. Thanks to a tailored design, calculation, production and testing, C POWER delivers the specified power reliably, without limitation, anytime.

The rotary converter benefits from a four-point access that ensures maximum service capability and benefits from an unrivalled Service life of >25years. Coupled with an extremely high MTBF of 50,000hours, means that the Hitzinger rotary converter provides an extremely reliable solution.

Trusted Across Critical Industries

Let’s Build Something Exceptional​

Our engineers are ready to help you design, deliver, and maintain systems built to last. Get in touch today.