S Power
Decentral Stationary
S POWER DECENTRAL STATIONARY
With its S POWER, Hitzinger presents a new standard of ground power generation for all aircrafts during the flight preparation phase. Optimized voltage quality and the highest level of supply security at maximum serviceability and simplified operation make S POWER Stack Technology combines active power factor correction with state of the art inverter technology.








Previous
Next
Technical data
Applications
- Fixed ground installation
- Bridge mounting
- Towable applications
- Towable applicationPower classess
- S POWER 45 to 180 kVA
- Economic Efficiency
- Efficiency ≥ 93%, independent of load profile
Technical data
Input:
- Voltage: 3x400V~ ± 10%, 3x480V~ ± 10%, other voltage ranges available upon request
- Frequency: 50/60Hz ± 5%
- Power factor: 0,99 via PFC (Power Factor Correction)
- Current distortion: < 5%
- Inrush current: none, (< Inominal)
Output:
- Power: 45 – 180kVA
- Power factor: 1,0
- Voltage: 3x115/200V
- Frequency: 400Hz
- Load power factor: 0,6 inductive to 0,95 capacitive
- Static voltage regulation: < 0,5%
- Crest factor: 1,414 ± 3%
- Phase angle symmetry: 120° ± 1° for balanced load, 120° ± 2° for 30% unbalanced load
- Total harmonic content: <2%
- Overload Characteristic
- 125% for 10min.
- 150% for 1min.
- 200% for 30sec.
- 200% for 30sec.
- 300% for 10sec.
- 400% for 1sec.
- Ambient temperature: -30 °C to +52 °C
- Relative humidity: 10 to 95 %
- Noise level: <65 dB (A) @ 1 m
- Standard Version
Standard cabinet
- IP-protection IP55
- Enclosure material: UV-resistant, powdercoated aluminium in RAL9006
- Frontdoor: PMMA(Polymethylmethacrylat), UV-, oil- , acid-, scratch-resistant
- Lockable door
Remote diagnosis
- Master/Slave
- Ventilation regulator including temperature monitoring
- Current operational condition
- Exact error notification
- Overload switch including temperature monitoring
- Compatible with div. operating systems (Windows, Linux)
Input:
- ISO 6858 - Aircraft ground support electrical supplies
- BS 2G 219 - General requirements for ground support equipment
- SAE ARP 5015 - Ground Equipment 400HZ ground power performance requirements
- DFS 400 - Specification for 400HZ aircraft power
- MIL-STD-704 - Aircraft electrical power characteristics
- EN2282 - Characteristics of aircraft electrical supplies
- EN61439 - Low-Voltage switchgear and controlgear assemblies
- EN61000-6-4 - Electromagnetic compatibility
- EN12312-20 - Specific requirements for electrical ground power units
- EN1915 -1/-2 - Aircraft ground support equipment, general safety requirements
- 28 VDC unit, 600/2500 A in stack technology
- remote control panel
- Additional output conductor
- LED indication (RGB)
- Potential-free-contacts
- Bus interface (MODBUS/TCP, Profibus)
- Neutral wire disruptuion monitoring
- Neutral voltage supervision
Technical highlights
From the installation to the first start and permanent application, S POWER sets itself apart with its reliability and its simple operation. Optimal voltage quality at maximum service security and serviceability power. Guaranteed power for all types of aircraft.